ecuador DC SOLAR PUMP Solar Powered Deep Well Pump

Product Description

● The leading manufactory for dc solar pumps in china
● Can be powered by both solar panel and battery
● Environmental protection,clean energy
● High efflciency permanent magnetic motor, officiency improved 15%-25%
● Over voltage protection
● Under voltage protection
● Locked rotor protection
● Low temperature rise
● Water supplyin rural area

 

Model

Dimensions(cm)

Weight(kg)

A

B

C

DC controller

23.8

18

9.5

1.5

 

 

 

 

Techincal Data

No.

ITEM

Voltage

Optimum input voltage(DC)

Power

Max.flow

Max. Head

Outlet

Cable

Solar panel

Open circuit

voltage(voc)

Power

01

3DC3-25-24-200

24V

30V-48V

200W

3.0m³/h

25m

1.25"

2m

<50V

≥1.3*PUMPPOWER

02

3DC3-35-24-300

24V

30V-48V

300W

3.0m³/h

35m

1.25"

2m

<50V

≥1.3*PUMPPOWER

03

3DC3.5-47-48-400

48V

60V-90V

400W

3.5m/h

47m

1.25"

2m

<100V

≥1.3*PUMPPOWER

04

3DC3.5-80-48-600

48V

60V-90V

600W

3.5m³/h

80m

1.25"

2m

<100V

≥1.3*PUMP POWER

05

3DC3.5-80.72.6o

72V

90V-120V

600W

3.5m³/h

80m

1.25"

2m

<150V

≥1.3*PUMP POWER

06

3DC3.5-95-48-750

48V

60V-90V

750W

3.5m²/h

95m

1.25"

2m

<100V

≥1.3*PUMPPOWER

07

3DC3.5-95-72-750

72V

90V-120V

750W

3.5m³/h

95m

1.25"

2m

<150V

≥1.3*PUMP POWER

08

3DC3.8-123-72-1100

72V

90V-120v

1100W

3.8m³/h

123m

1.25"

2m

<150V

≥1.3*PUMP POWER

09

3DC3.8-123-110-1100

110V

110V-150V

1100W

3.8m³/h

123m

1.25"

2m

<200V

≥1.3*PUMP POWER

10

3DC3.8-155-110-1300

110v

110V-150V

1300W

3.8m³/h

155m

1.25"

2m

<200V

≥1.3*PUMP POWER

11

3DC3.8-180-110-1500

110V

110V-150V

1500W

3.8m³/h

180m

1.25"

2m

<200V

≥1.3*PUMP POWER

 

 

 

No.

ITEM

Voltage

Optimum input voltage(DC)

Power

Max.flow

Max. Head

Outlet

Cable

Solar panel

Open circuit

voltage(voc)

Power

01

3DC5-45-48-500

48V

60V-90V

500W

5m³/h

45m

1.5"

2m

<100V

≥1.3*PUMPPOWEF

02

3DC5.2-50-48-600

48V

60V-90V

600W

5.2m³/h

50m

1.5"

2m

<100V

≥1.3*PUMPPOWER

03

3DC5.2-50-72-600

72V

90V-120V

600W

5.2m³/h

50m

1.5"

2m

<150V

≥1.3*PUMP POWER

04

3DC5.2-75-110-750

110V

110V-150V

750W

5.2m³/h

75m

1.5"

2m

<200V

≥1.3*PUMP POWER

05

3DC5.5-65-72-750

72V

90V-120V

750W

5.5m³/h

65m

1.5"

2m

<150V

≥1.3*PUMP POWER

06

3DC5.5-65-110-750

110V

110V-150V

750W

5.5m³/h

65m

1.5"

2m

<200V

≥1.3*PUMP POWER

07

3DC6-84-110-1100

110V

110V-150V

1100W

6m³/h

84m

1.5"

2m

<200V

≥1.3*PUMP POWFE

08

3DC6-125-110-1500

110V

110V-150V

1500W

6m³/h

125m

1.5"

2m

<200V

≥1.3*PUMP POWER

09

3DC7-46-72-750

72V

90V-120V

750W

7m³h

46m

1.5"

2m

<150V

≥1.3*PUMP POWER

10

3DC7-46-110-750

110V

110V-150V

750W

7m²/h

46m

1.5"

2m

<200V

≥1.3*PUMP POWER

11

3DC7.5-62-110-1100

110V

110V-150V

1100W

7.5m³/h

62m

1.5"

2m

<200V

≥1.3*PUMP POWER

12

3DC7.5-78-110-1500

110V

110V-150V

1500W

7.5m³/h

78m

1.5"

2m

<200V

≥1.3*PUMPPOWER

 

 

 

No.

ITEM

Voltage

Optimum input voltage(DC)

Power

Max.flow

Max. Head

Outlet

Cable

Solar panel

Open circuit

voltage(voc)

Power

01

4DC3.6-52-48-300

48V

60V-90V

300W

3.6m³/h

52m

1.25"

2m

<50V

≥1.3'PUMP POWER

02

4DC3.9-100-48-750

48V

60V-90V

750W

3.6m³

101m

1.25"

2m

<100V

≥1.3*PUMP POWER

03

4DC3.9-100-72-750

72V

90V-120V

750W

3.9m'/h

100m

1.25"

2m

<150V

≥1.3*PUMP POWER

03

4DC6-42-48-600

48V

60V-90V

600W

6.0m³/h

42m

1.25"

2m

<150V

≥1.3*PUMPPOWER

04

4DC6-42-72-600

72V

90V-120V

600W

6.0m³/h

42m

1.25"

2m

<150V

≥1.3*PUMP POWER

05

4DC6-56-48-750

48V

60V-90V

750W

6.0m/h

56m

1.25"

2m

<100V

≥1.3*PUMP POWER

06

4DC6-56-72-750

72V

90V-120V

750W

6.0m²/h

56m

1.25"

2m

<150V

≥1.3*PUMP POWER

07

4DC6-84-72-1100

72V

90V-120V

1100W

6.0m³/h

84m

1.25"

2m

<150V

≥1.3*PUMP POWEF

08

4DC6-84-110-1100

110V

110V-150V

1100W

6.0m³/h

84m

1.25"

2m

<200V

≥1.3*PUMP POWER

09

4DC6-112-110-1300

110V

110V-150V

1300W

6.0m³/h

112m

1.25"

2m

<200V

≥1.3*PUMP POWER

10

4DC6-135-110-1500

110V

110V-150V

1500W

6.0m³/h

135m

1.25"

2m

<200V

≥1.3*PUMP POWER

 

 

 

No.

ITEM

Voltage

Optimum input voltage(DC)

Power

Max.flow

Max. Head

Outlet

Cable

Solar panel

Open circuit

voltage(voc)

Power

01

4DC9-45-110-750

110V

110V-150V

750W

9.0m³/h

45m

2"

2m

<200V

≥1.3*PUMP POWER

02

4DC9-58-110-1100

110V

110V-150V

1100W

9.0m³/h

58m

2"

2m

<200V

≥1.3*PUMP POWER

03

4DC9-71-110-1300

110V

110V-150V

1300W

9.0m³/h

71m

2"

2m

<200V

≥1.3*PUMP POWER

04

4DC9-85-110-1500

110V

110V-150V

1500W

9.0m³/h

85m

2"

2m

<200V

≥1.3*PUMP POWFR

05

4DC13-36-110-750

110V

110V-150V

750W

13.0m²/h

36m

2"

2m

<200V

≥1.3*PUMP POWER

06

4DC13-49-110-1100

110V

10V-150V

1100W

13.0m³/h

49m

2"

2m

<200V

≥1.3*PUMP POWE

07

4DC13-54-110-1300

110V

110V-150V

1300W

13.0m³/h

54m

2"

2m

<200V

≥1.3*PUMP POWER

08

4DC13-60-110-1500

110V

110V-150V

1500W

13.0m³/h

60m

2"

2m

<200V

≥1.3*PUMP POWER

09

4DC17-48-110-1500

110V

110V-150y

1500W

17.0m³/h

48m

2"

2m

<200V